Перевод: с русского на все языки

со всех языков на русский

electric arc phenomenon

  • 1 явление электрической дуги

    1. electric arc phenomenon

     

    явление электрической дуги
    -
    [Интент]

    Параллельные тексты EN-RU

    Electric arc phenomenon

    The electric arc is a phenomenon which takes place as a consequence of a discharge which occurs when the voltage between two points exceeds the insulating strength limit of the interposed gas; then, in the presence of suitable conditions, a plasma is generated which carries the electric current till the opening of the protective device on the supply side.

    Gases, which are good insulating means under normal conditions, may become current conductors in consequence of a change in their chemical-physical properties due to a temperature rise or to other external factors.

    To understand how an electrical arc originates, reference can be made to what happens when a circuit opens or closes.

    During the opening phase of an electric circuit the contacts of the protective device start to separate thus offering to the current a gradually decreasing section; therefore the current meets growing resistance with a consequent rise in the temperature.

    As soon as the contacts start to separate, the voltage applied to the circuit exceeds the dielectric strength of the air, causing its perforation through a discharge.

    The high temperature causes the ionization of the surrounding air which keeps the current circulating in the form of electrical arc. Besides thermal ionization, there is also an electron emission from the cathode due to the thermionic effect; the ions formed in the gas due to the very high temperature are accelerated by the electric field, strike the cathode, release energy in the collision thus causing a localized heating which generates electron emission.

    The electrical arc lasts till the voltage at its ends supplies the energy sufficient to compensate for the quantity of heat dissipated and to maintain the suitable conditions of temperature. If the arc is elongated and cooled, the conditions necessary for its maintenance lack and it extinguishes.

    Analogously, an arc can originate also as a consequence of a short-circuit between phases. A short-circuit is a low impedance connection between two conductors at different voltages.

    The conducting element which constitutes the low impedance connection (e.g. a metallic tool forgotten on the busbars inside the enclosure, a wrong wiring or a body of an animal entered inside the enclosure), subject to the difference of potential is passed through by a current of generally high value, depending on the characteristics of the circuit.

    The flow of the high fault current causes the overheating of the cables or of the circuit busbars, up to the melting of the conductors of lower section; as soon as the conductor melts, analogous conditions to those present during the circuit opening arise. At that point an arc starts which lasts either till the protective devices intervene or till the conditions necessary for its stability subsist.

    The electric arc is characterized by an intense ionization of the gaseous means, by reduced drops of the anodic and cathodic voltage (10 V and 40 V respectively), by high or very high current density in the middle of the column (of the order of 102-103 up to 107 A/cm2), by very high temperatures (thousands of °C) always in the middle of the current column and – in low voltage - by a distance between the ends variable from some microns to some centimeters.

    [ABB]

    Явление электрической дуги

    Электрическая дуга между двумя электродами в газе представляет собой физическое явление, возникающее в тот момент, когда напряжения между двумя электродами превышает значение электрической прочности изоляции данного газа.
    При наличии подходящих условий образуется плазма, по которой протекает электрический ток. Ток будет протекать до тех пор, пока на стороне электропитания не сработает защитное устройство.

    Газы, являющиеся хорошим изолятором, при нормальных условиях, могут стать проводником в результате изменения их физико-химических свойств, которые могут произойти вследствие увеличения температуры или в результате воздействия каких-либо иных внешних факторов.

    Для того чтобы понять механизм возникновения электрической дуги, следует рассмотреть, что происходит при размыкании или замыкании электрической цепи.

    При размыкании электрической цепи контакты защитного устройства начинают расходиться, в результате чего постепенно уменьшается сечение контактной поверхности, через которую протекает ток.
    Сопротивление электрической цепи возрастает, что приводит к увеличению температуры.

    Как только контакты начнут отходить один от другого, приложенное напряжение превысит электрическую прочность воздуха, что вызовет электрический пробой.

    Высокая температура приведет к ионизации воздуха, которая обеспечит протекание электрического тока по проводнику, представляющему собой электрическую дугу. Кроме термической ионизации молекул воздуха происходит также эмиссия электронов с катода, вызванная термоэлектронным эффектом. Образующиеся под воздействием очень высокой температуры ионы ускоряются в электрическом поле и бомбардируют катод. Высвобождающаяся, в результате столкновения энергия, вызывает локальный нагрев, который, в свою очередь, приводит к эмиссии электронов.

    Электрическая дуга длится до тех пор, пока напряжение на ее концах обеспечивает поступление энергии, достаточной для компенсации выделяющегося тепла и для сохранения условий поддержания высокой температуры. Если дуга вытягивается и охлаждается, то условия, необходимые для ее поддержания, исчезают и дуга гаснет.

    Аналогичным образом возникает дуга в результате короткого замыкания электрической цепи. Короткое замыкание представляет собой низкоомное соединение двух проводников, находящихся под разными потенциалами.

    Проводящий элемент с малым сопротивлением, например, металлический инструмент, забытый на шинах внутри комплектного устройства, ошибка в электромонтаже или тело животного, случайно попавшего в комплектное устройство, может соединить элементы, находящиеся под разными потенциалами, в результате чего через низкоомное соединение потечет электрический ток, значение которого определяется параметрами образовавшейся короткозамкнутой цепи.

    Протекание большого тока короткого замыкания вызывает перегрев кабелей или шин, который может привести к расплавлению проводников с меньшим сечением. Как только проводник расплавится, возникает ситуация, аналогичная размыканию электрической цепи. Т. е. в момент размыкания возникает дуга, которая длится либо до срабатывания защитного устройства, либо до тех пор, пока существуют условия, обеспечивающие её стабильность.

    Электрическая дуга характеризуется интенсивной ионизацией газов, что приводит к падению анодного и катодного напряжений (на 10 и 40 В соответственно), высокой или очень высокой плотностью тока в середине плазменного шнура (от 102-103 до 107 А/см2), очень высокой температурой (сотни градусов Цельсия) всегда в середине плазменного шнура и низкому падению напряжения при расстоянии между концами дуги от нескольких микрон до нескольких сантиметров.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    EN

    Русско-английский словарь нормативно-технической терминологии > явление электрической дуги

  • 2 НКУ с устройствами ограничения воздействия внутренней дуги

    1. assembly equipped with devices limiting internal arc effects

     

    НКУ с устройствами ограничения воздействия внутренней дуги
    -
    [Интент]

    Параллельные тексты EN-RU

    Assemblies equipped with devices limiting internal arc effects (active protection)

    A design philosophy which is completely different from that just considered consists in guaranteeing the resistance to internal arcing by installing devices limiting the arc.

    The approaches in that direction can be of two different types:
    • limiting the destructive effects of the arc, once it has occured, by means of arc detectors
    • limiting the destructive effects of the arc, once it has occured, by means of overpressure detectors.

    The first possibility consists in installing in the assembly arc detectors which sense the light flux associated with the electric arc phenomenon.

    Once the arc has been detected, these devices send an opening signal to the incoming circuit-breaker, thus guaranteeing tripping times of the order of 1-2 ms, therefore shorter than those proper of the circuit-breaker.

    The operating logic of an arc detector is the following: the occurrence of an arc inside the switchboard is detected by the arc detector because an intense light radiation is associated with this phenomenon.

    The arcing control system detects the event and sends a tripping signal to the circuit-breaker.

    All the above with trip times of a few milliseconds and supplanting the tripping of the CB overcurrent relay which, for example, could be delayed due to current selectivity questions.

    Figure 1 shows the possible positions where this device can be installed inside a switchboard.

    The ideal solution is that which provides the installation of at least one detector for each column, with the consequent reduction to a minimum of the length of the optical fibers carrying the signal.

    In order to prevent from an unwanted tripping caused by light sources indepent of the arc (lamps, solar radiation etc.), an additional current sensor is often positioned at the incoming of the main circuit-breaker.

    Only in the event of an arc, both the incoming sensor which detects an “anomalous” current due to the arc fault as well as the sensor detecting the light radiation as sociated with the arc enable the system to intervene and allow the consequent opening of the circuit-breaker.

    The second possibility consists in installing overpressure sensors inside the switchboard.

    As previously described, the overpressure wave is one of the other effects occurring inside an assembly in case of arcing.

    As a consequence it is possible to install some pressure sensors which are able to signal the pressure peak associated with the arc ignition with a delay of about 10-15 ms.

    The signal operates on the supply circuit-breaker without waiting for the trip times of the selectivity protections to elapse, which are necessarily longer.

    Such a system does not need any electronic processing device, since it acts directly on the tripping coil of the supply circuit-breaker.

    Obviously it is essential that the device is set at fixed trip thresholds.

    When an established internal overpressure is reached, the arc detector intervenes.

    However, it is not easy to define in advance the value of overpressure generated by an arc fault inside a switchboard.

    [ABB]

    НКУ с устройствами ограничения воздействия внутренней дуги (активная защита)

    Для решения этой задачи используются совершенно другие, отличающиеся от ранее рассмотренных, принципы, заключающиеся в том, что противодействие внутренней дуге обеспечивается применением устройств, ограничивающих саму дугу.

    Существует два типа решения проблемы в этом направлении:
    • ограничение разрушающего воздействия дуги после того, как ее обнаружат специальные устройства
    • ограничение разрушающего воздействия дуги после того, как специальные устройства обнаружат возникновение избыточного давления.

    В первом случае в НКУ устанавливают устройства обнаружения дуги, реагирующие на световой поток, сопровождающий явление электрической дуги.

    При обнаружении дуги данные устройства посылают сигнал управления на размыкание вводного автоматического выключателя. Гарантируемое время реакции составляет 1-2 мс, что меньше времени срабатывания автоматического выключателя.

    Логика работы устройства обнаружения дуги следующая: Дуга, возникшая внутри НКУ, обнаруживается датчиком, реагирующим на интенсивное световое излучение, которым сопровождается горение дуги.

    Обнаружив дугу, система управления посылает сигнал автоматическому выключателю.

    Время срабатывания датчика и системы управления составляет несколько миллисекунд, что меньше времени срабатывания автоматического выключателя, осуществляющего защиту от сверхтока, который обычно для обеспечения требуемой селективности срабатывает с задержкой.

    На рис. 1 показаны места возможной установки устройства защиты внутри НКУ.

    Идеальным решением является установка, по крайней мере, одного устройства защиты в каждый шкаф многошкафного НКУ.

    Это позволит до минимума сократить длину оптоволоконных кабелей передачи сигнала.

    Для предотвращения ложного срабатывания от других источников света (т. е. не от дуги), например, таких как лампы, солнечное излучение и т. п., дополнительно в главной цепи вводного автоматического выключателя устанавливают датчик тока.

    Только при наличии двух событий, а именно: срабатывания датчика света и обнаружения аномального увеличения тока, система управления считает, что возникла электрическая дуга и подает команду на отключение вводного автоматического выключателя.

    Второе решение заключается в установке внутри НКУ датчика избыточного давления.

    Как было описано ранее, одним из характерных проявлений электрической дуги, возникшей внутри НКУ, является ударная волна.

    Это означает, что можно установить несколько датчиков давления, задачей которых является обнаружение импульса давления (с задержкой 10…15 мс), обусловленного зажиганием дуги.

    Сигнал от датчиков давления поступает на вводной автоматический выключатель, который срабатывает без задержки на обеспечение селективности.

    Такая система не нуждается в электронном устройстве обработки информации, поскольку воздействует непосредственно на независимый расцепитель автоматического выключателя.

    Вполне понятно, что такое устройство имеет фиксированный порог срабатывания.

    Датчик-реле дуги сработает, как только будет достигнуто заданное значение избыточного давления.

    Следует иметь в виду, что не так легко заранее определить значение избыточного давления, которое будет создано при зажигании дуги внутри НКУ.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    EN

    Русско-английский словарь нормативно-технической терминологии > НКУ с устройствами ограничения воздействия внутренней дуги

  • 3 электрическая дуга

    1. arc électrique
    2. arc

     

    электрическая дуга
    -
    [Интент]

    EN

    (electric) arc
    self-maintained gas conduction for which most of the charge carriers are electrons supplied by primary‑electron emission
    [IEV ref 121-13-12]

    FR

    arc (électrique), m
    conduction gazeuse autonome dans laquelle la plupart des porteurs de charge sont des électrons produits par émission électronique primaire
    [IEV ref 121-13-12]

     


    An electric arc is an electrical breakdown of a gas which produces an ongoing plasma discharge, resulting from a current flowing through normally nonconductive media such as air. A synonym is arc discharge. An arc discharge is characterized by a lower voltage than a glow discharge, and relies on thermionic emission of electrons from the electrodes supporting the arc. The phenomenon was first described by Vasily V. Petrov, a Russian scientist who discovered it in 1802. An archaic term is voltaic arc as used in the phrase " voltaic arc lamp".
    [http://en.wikipedia.org/wiki/Electric_arc]

    Параллельные тексты EN-RU

    In the last years a lot of users have underlined the question of safety in electrical assemblies with reference to one of the most severe and destructive electrophysical phenomenon: the electric arc.
    [ABB]

    В последние годы многие потребители обращают особое внимание на безопасность НКУ, связанную с чрезвычайно разрушительным и наиболее жестко действующим электрофизическим явлением - электрической дугой.
    [Перевод Интент]

    Тематики

    • электротехника, основные понятия

    Действия

    Сопутствующие термины

    EN

    DE

    • elektrischer Lichtbogen, m
    • Lichtbogen, m

    FR

    Русско-французский словарь нормативно-технической терминологии > электрическая дуга

  • 4 электрическая дуга

    1. voltaic arc
    2. electric arc
    3. arc

     

    электрическая дуга
    -
    [Интент]

    EN

    (electric) arc
    self-maintained gas conduction for which most of the charge carriers are electrons supplied by primary‑electron emission
    [IEV ref 121-13-12]

    FR

    arc (électrique), m
    conduction gazeuse autonome dans laquelle la plupart des porteurs de charge sont des électrons produits par émission électronique primaire
    [IEV ref 121-13-12]

     


    An electric arc is an electrical breakdown of a gas which produces an ongoing plasma discharge, resulting from a current flowing through normally nonconductive media such as air. A synonym is arc discharge. An arc discharge is characterized by a lower voltage than a glow discharge, and relies on thermionic emission of electrons from the electrodes supporting the arc. The phenomenon was first described by Vasily V. Petrov, a Russian scientist who discovered it in 1802. An archaic term is voltaic arc as used in the phrase " voltaic arc lamp".
    [http://en.wikipedia.org/wiki/Electric_arc]

    Параллельные тексты EN-RU

    In the last years a lot of users have underlined the question of safety in electrical assemblies with reference to one of the most severe and destructive electrophysical phenomenon: the electric arc.
    [ABB]

    В последние годы многие потребители обращают особое внимание на безопасность НКУ, связанную с чрезвычайно разрушительным и наиболее жестко действующим электрофизическим явлением - электрической дугой.
    [Перевод Интент]

    Тематики

    • электротехника, основные понятия

    Действия

    Сопутствующие термины

    EN

    DE

    • elektrischer Lichtbogen, m
    • Lichtbogen, m

    FR

    Русско-английский словарь нормативно-технической терминологии > электрическая дуга

  • 5 электрическая дуга

    1. Lichtbogen, m
    2. elektrischer Lichtbogen, m

     

    электрическая дуга
    -
    [Интент]

    EN

    (electric) arc
    self-maintained gas conduction for which most of the charge carriers are electrons supplied by primary‑electron emission
    [IEV ref 121-13-12]

    FR

    arc (électrique), m
    conduction gazeuse autonome dans laquelle la plupart des porteurs de charge sont des électrons produits par émission électronique primaire
    [IEV ref 121-13-12]

     


    An electric arc is an electrical breakdown of a gas which produces an ongoing plasma discharge, resulting from a current flowing through normally nonconductive media such as air. A synonym is arc discharge. An arc discharge is characterized by a lower voltage than a glow discharge, and relies on thermionic emission of electrons from the electrodes supporting the arc. The phenomenon was first described by Vasily V. Petrov, a Russian scientist who discovered it in 1802. An archaic term is voltaic arc as used in the phrase " voltaic arc lamp".
    [http://en.wikipedia.org/wiki/Electric_arc]

    Параллельные тексты EN-RU

    In the last years a lot of users have underlined the question of safety in electrical assemblies with reference to one of the most severe and destructive electrophysical phenomenon: the electric arc.
    [ABB]

    В последние годы многие потребители обращают особое внимание на безопасность НКУ, связанную с чрезвычайно разрушительным и наиболее жестко действующим электрофизическим явлением - электрической дугой.
    [Перевод Интент]

    Тематики

    • электротехника, основные понятия

    Действия

    Сопутствующие термины

    EN

    DE

    • elektrischer Lichtbogen, m
    • Lichtbogen, m

    FR

    Русско-немецкий словарь нормативно-технической терминологии > электрическая дуга

  • 6 действие электрической дуги, возникающей внутри НКУ распределения и управления

    1. effects of the electric arc inside switchgear and controlgear assemblу

     

    действие электрической дуги, возникающей внутри НКУ распределения и управления
    -
    [Интент]

    Параллельные тексты EN-RU

    Effects of the electric arc inside switchgear and controlgear assemblies

    In the proximity of the main boards, i.e. in the proximity of big electrical machines, such as transformers or generators, the short-circuit power is high and consequently also the energy associated with the electrical arc due to a fault is high.

    Without going into complex mathematical descriptions of this phenomenon, the first instants of arc formation inside a cubicle can be schematized in 4 phases:

    1. compression phase: in this phase the volume of the air where the arc develops is overheated owing to the continuous release of energy; due to convection and radiation the remaining volume of air inside the cubicle warms up; initially there are temperature and pressure values different from one zone to another;

    2. expansion phase: from the first instants of internal pressure increase a hole is formed through which the overheated air begins to go out. In this phase the pressure reaches its maximum value and starts to decrease owing to the release of hot air;

    3. emission phase: in this phase, due to the continuous contribution of energy by the arc, nearly all the air is forced out under a soft and almost constant overpressure;

    4. thermal phase: after the expulsion of the air, the temperature inside the switchgear reaches almost that of the electrical arc, thus beginning this final phase which lasts till the arc is quenched, when all the metals and the insulating materials coming into contact undergo erosion with production of gases, fumes and molten material particles.

    Should the electrical arc occur in open configurations, some of the described phases could not be present or could have less effect; however, there shall be a pressure wave and a rise in the temperature of the zones surrounding the arc.

    Being in the proximity of an electrical arc is quite dangerous; here are some data to understand how dangerous it is:

    • pressure: at a distance of 60 cm from an electrical arc associated with a 20 kA arcing fault a person can be subject to a force of 225 kg; moreover, the sudden pressure wave may cause permanent injuries to the eardrum;
    • arc temperatures: about 7000-8000 °C;
    • sound: electrical arc sound levels can reach 160 db, a shotgun blast only 130 db.

    [ABB]

    Действие электрической дуги, возникающей внутри НКУ распределения и управления

    Короткое замыкание вблизи больших силовых устройств, таких как трансформаторы или генераторы имеет очень большую мощность. Поэтому энергия электрической дуги, возникшей в результате короткого замыкания, очень большая.

    Не вдаваясь в сложное математическое описание данного явления, можно сказать, что первые мгновения формирования дуги внутри шкафа можно упрощенно разделить на четыре этапа:

    1. Этап сжатия: на этом этапе объем воздуха, в котором происходит зарождение дуги перегревается вследствие непрерывного высвобождения энергии. За счет конвекции и излучения оставшийся объем воздуха внутри шкафа нагревается. На этом начальном этапе значения температуры и давления воздуха в разных зонах НКУ разные.

    2. Этап расширения: с первых мгновений внутреннее давление создает канал, через который начинается движение перегретого воздуха. На этом этапе давление достигает своего максимального значения, после чего начинает уменьшаться вследствие выхода горячего воздуха.

    3. Этап эмиссии: на этом этапе вследствие непрерывного пополнения энергией дуги почти весь воздух выталкивается под действием мягкого и почти постоянного избыточного давления.

    4. Термический этап: после выхлопа воздуха температура внутри НКУ почти достигает температуры электрической дуги. Так начинается заключительный этап, который длится до тех пор, пока дуга не погаснет. При этом все металлические и изоляционные материалы, вступившие в контакт с дугой, оказываются подвергнутыми эрозии с выделением газов, дыма и частиц расплавленного материала.

    Если электрическая дуга возникнет в открытом НКУ, то некоторые из описанных этапов могут не присутствовать или могут иметь меньшее воздействие. Тем не менее будет иметь место воздушная волна и подъем температуры вблизи дуги.

    Находиться вблизи электрической дуги довольно опасно. Ниже приведены некоторые сведения, помогающие осознать эту опасность:

    • давление: На расстоянии 60 см от электрической дуги, вызванной током короткого замыкания 20 кА, человек может подвергнуться воздействию силы 225 кг. Более того, резкая волна давления может нанести тяжелую травму барабанным перепонкам;
    • температура дуги: около 7000-8000 °C;
    • шумовое воздействие: Уровень шумового воздействия электрической дуги может достигнуть 160 дБ (выстрел из дробовика – 130 дБ).

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    EN

    Русско-английский словарь нормативно-технической терминологии > действие электрической дуги, возникающей внутри НКУ распределения и управления

См. также в других словарях:

  • Electric arc — An electric arc is an electrical breakdown of a gas which produces an ongoing plasma discharge, resulting from a current flowing through normally nonconductive media such as air. A synonym is arc discharge. The phenomenon was first described by… …   Wikipedia

  • Arc — may refer to: Computing and gaming*Arc (programming language), a Lisp dialect in development by Paul Graham *.arc, a file extension for archive files *arc, the command line interface for ArcInfo *Arc System Works, a video game… …   Wikipedia

  • Optical phenomenon — An optical phenomenon is any observable event that results from the interaction of light and matter. See also list of optical topics and optics. A mirage is an example of an optical phenomenon. Common optical phenomena are often due to the… …   Wikipedia

  • явление электрической дуги — [Интент] Параллельные тексты EN RU Electric arc phenomenon The electric arc is a phenomenon which takes place as a consequence of a discharge which occurs when the voltage between two points exceeds the insulating strength limit of the interposed …   Справочник технического переводчика

  • НКУ с устройствами ограничения воздействия внутренней дуги — [Интент] Параллельные тексты EN RU Assemblies equipped with devices limiting internal arc effects (active protection) A design philosophy which is completely different from that just considered consists in guaranteeing the resistance to internal… …   Справочник технического переводчика

  • History of electromagnetism — The history of electromagnetism, that is the human understanding and recorded use of electromagnetic forces, dates back over two thousand years ago, see Timeline of electromagnetism. The ancients must have been acquainted with the effects of… …   Wikipedia

  • electromagnetism — /i lek troh mag ni tiz euhm/, n. 1. the phenomena associated with electric and magnetic fields and their interactions with each other and with electric charges and currents. 2. Also, electromagnetics. the science that deals with these phenomena.… …   Universalium

  • spectroscopy — spectroscopist /spek tros keuh pist/, n. /spek tros keuh pee, spek treuh skoh pee/, n. the science that deals with the use of the spectroscope and with spectrum analysis. [1865 70; SPECTRO + SCOPY] * * * Branch of analysis devoted to identifying… …   Universalium

  • steel — steellike, adj. /steel/, n. 1. any of various modified forms of iron, artificially produced, having a carbon content less than that of pig iron and more than that of wrought iron, and having qualities of hardness, elasticity, and strength varying …   Universalium

  • Mathematics and Physical Sciences — ▪ 2003 Introduction Mathematics       Mathematics in 2002 was marked by two discoveries in number theory. The first may have practical implications; the second satisfied a 150 year old curiosity.       Computer scientist Manindra Agrawal of the… …   Universalium

  • plasma — plasmatic /plaz mat ik/, plasmic, adj. /plaz meuh/, n. 1. Anat., Physiol. the liquid part of blood or lymph, as distinguished from the suspended elements. 2. Cell Biol. cytoplasm. 3. whey. 4. a green, faintly translucent chalcedony. 5. Physics. a …   Universalium

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»